Basically, the VTR series consists of a rotor, the housing and the measurement pick-up. The flow of fluid activates the rotor. When the rotor blades interrupt the magnetic field lines of the pick-up system, the motion of the rotor is detected. As a result of the specific inner diameter, the turbine's revolutions are directly proportional to the flow.
Performance data
Flow range 110 l/h up to 7.500 m3/h
Pressure range up to 250 bar
Temperature range – 40°C up to +120°C
Frequency range up to 1.300 Hz
Viscosity range 1 up to 5 cSt
Applications
Water-like substances
Water
Oils
Petrochemicals