VSE optimized material and technology in the bearing area. The combined radial / axial slide bearing is shielded behind bearing brackets shaped to be flow-optimized. The bearings are made from tungsten carbide and, first time in positive displacement flow meter, also made from silicium carbide (SSiC).
A sensor module was developed that enhances the functionality of the RS flow meter significantly. The sensor itself features two GMR bridges (sin / cos) and is housed in a removable stainless steel cartridge case together with a signal conditioning and amplifier unit. The downstream electronics unit features a high-resolution sin / cos-interpolator. Among others, the device features a programmable signal filter, which is able to offset unwanted, negative pulse sequences and detects and saves values that exceed the indicated flow and temperature values. A separate directional signal is available for 1-channel evaluations.
Performance data
Flow range 0 up to 3.000 l/min
Pressure range up to 450 bar
Temperature range -30 up to +120°C
Frequency range up to 100 kHz
Viscosity range 1 up to 1.000.000 cSt
Applications
Process technology
Hydraulics
Highly viscous, paste-like, abrasive adhesives and sealants
Advantages
High precision mostly independent of viscosity
Gentle fluid measurement
Pulsation-free measurement
Lowest pressure losses
High on functionality due to intelligent sensor technology
Short response time through reduced mass